说明 :此机型停产,规格机型为SY-8218 (高频10MHZ)及SY-8219 (1MHZ)

详情介绍
Features:

Ultrawide measurement frequency


bandwidth

-The frequency range for measurement is exceptionally wide, from 10 Hz (optionally 1 Hz) to 10 MHz.


Desktop size, all-in-one construction
-A compact design incorporating an oscillation circuit, power amplifier circuit, high-speed digitizer, operation control circuit and printer. Magnetic head material can be directly measured by the built-in power amplifier (25 VA) for excitation. (An optional external power
amplifier can also be used.)


Continuous measurement function and an extensive selection of other measuring functions
-Continuous measurement with up to 12 steps, and various measurements including a B-H curve, core loss curve, µ- characteristics and L-characteristics, are available.


High-speed, high-precision measurement
-High-speed measurement in approx. 3 seconds can be performed. In addition, an FFT arithmetic circuit permits automatic compensation and calibration of frequency characteristics, enabling high-precision
measurements.


Printer provided as standard (built-in)
-Measurement results can be printed out immediately. Convenient for data sorting.


GP-IB interface provided as standard
-An automated measurement system in combination with a PC can be configured.


Easy-to-view 9-inch color CRT display


Easy operation with pop-up menu system
-Pop-up menus are displayed on the CRT to facilitate operation.
-Results are displayed as graphs or lists.

Enhanced measurement efficiency with a wide range of options
-Options include an external power amplifier and sample connection pod for various use.


Description

The SY-8232 high-frequency B-H analyzer is the flagship of IWATSU’s line of B-H analyzers.

It has a high-frequency B-H curve tracing capability over an ultrawide-range measurement frequency from 10 Hz (optionally 1 Hz) to 10 MHz.

The SY-8232’s compact design makes it ideal for desktop use. It incorporates features required for measuring high-frequency magnetic characteristics, including an oscillation circuit, power amplifier circuit, high-speed digitizer, operation control circuit and a printer.

The built-in 25 VA power amplifier allows direct measurement of small specimens such as magnetic heads, while use of an external power amplifier enables measurement of large amplitude characteristics and saturation characteristics of power ferrite or ultrathin amorphous materials. The lower limit frequency is as low as 10 Hz (optionally 1 Hz), permitting the measurement of near DC magnetic characteristics of soft magnetic materials. As the analyzer allows both near DC and AC, the measurements of coercive force (Hc) related to magnetic wall production, migration and extinction can be more effective and research and testing in materials development can be performed more quickly.


Specifications


Measurement modes

Core loss measurement: Frequency (f) or maximum magnetic flux density (Bm) can be varied.
B-H curve measurement: Frequency (f) or maximum magnetic field (Hm) can be varied.
Permeability measurement: Frequency (f) can be varied.

Measured items

Core loss measurement: Max. magnetic flux density (Bm), residual magnetic flux density (Br), max. magnetic field (Hm), coercive force (Hc), core loss (Pc, Pcv, Pcm), phase (q), amplitude permeability (µa), hysteresis loss (Ph), eddy-current loss (Pe).
B-H curve measurement: Max. magnetic flux density (Bm), residual magnetic flux density (Br), max. magnetic field (Hm), coercive force (Hc), core loss (Pc, Pcv, Pcm), phase (q), amplitude permeability (µa), differential permeability (µdiff), square ratio (Br/Bm), total magnetic flux change (2f m)
Permeability measurement: Max. magnetic flux density (Bm), max. magnetic field (Hm), core loss (Pc), phase (q), amplitude permeability (µa), inductance (L), complex permeability (µ’, µ").

Operation modes

Single: One measurement step with one operation.
Continuous: Up to 12-step preset schedules (frequencies or amplitudes) can be measured continuously with one operation.

Set frequency

10 Hz (optionally 1 Hz) to 10 MHz, 2 digits effective
Accuracy: ±0.1% for the set value.

Measurement time

Approx. 3 sec./step (when the measured frequency is 1 kHz or more)

Oscillating section

Oscillation frequency: 10 Hz to 10 MHz, sine wave
Output voltage/resistance: 0 to ±2.5 V/50 ½
Built-in excitation control in 3 steps of approximate value, asymptotic and demagnetization.

Excitation section

Output voltage ±50 V max., output current ±1 A max. ( 1.1 kHz) or ±4 A max. (10 Hz (optionally 1 Hz) to 1 kHz).
Output impedance 1 ½ + 0.1 µH, output power 25 VA.

Detection section (standard)

Excitation current detection
System: Voltage drop across two ends of non-inductive resistance.
Detection sensitivity: ±50 mA to ±5 A (1-2-5 steps)
Frequency bandwidth: DC to 100 MHz


Magnetic flux detection
System: Detection of voltage (induced voltage) across two ends of detection coil.
Detection sensitivity: ±50 mA to ±50 V (1-2-5 steps)
Frequency bandwidth: DC to 100 MHz

Storage section

Sampling rate: 512 times the set frequency (synchronized with the built-in oscillator).
Resolution: 16 bits

Display section

System: 9-inch color CRT
Contents: Measuring condition, characteristic values, B-H curve, characteristic graphs

Printer (Built-in)

Heat-sensitive dot line system. Paper width approx. 112 mm, printing time no more than approx. 5 sec.

External interface

GP-IB interface

Power supply

100 V AC (90 ~ 132 V) or 200 V AC (180 – 250 V) models.Approx. 800 W (100 V AC)

Dimensions & weight

Main unit: Approx. 420W x 350H x 520L mm (excluding the pod), approx. 34 kg (SY-8232 mainframe + SY-301 measurement unit)

Environment

Operating temperatures +5°C to +35°C (+10°C to +30°C when the printer is used)

Performance guaranteed temperatures

+18°C to +28°C

Provided accessories

SY-921 measurement pod (1 set), power cords (2), connection cables (1 set), estimation samples (1 set), adapters for calibration (1 set), Thermal paper (2 rolls), fuses (4), instruction manual (1), dust cover (1), accessory case (1).


Models, Options, & Accessories


Model

Description

List Price

Sale Price

SY-8232

Please call or us for pricing and availability.

Model

Accessories

List Price

Sale Price

SY-922

Please call or us for pricing and availability.

SY-931

Please call or us for pricing and availability.

SY-927

Please call or us for pricing and availability.

SY-928

Please call or us for pricing and availability.

SY-937

Please call or us for pricing and availability.

SY-924

Please call or us for pricing and availability.



上一篇: NF HSA42014/42011/42012宽频1MHZ四象
下一篇: XITRON 2000MN 2000IN 思创 标准源 校
我要评论
文明上网,理性发言。(您还可以输入200个字符)

所有评论仅代表网友意见,与本站立场无关。

请选择省份

  • 安徽
  • 北京
  • 福建
  • 甘肃
  • 广东
  • 广西
  • 贵州
  • 海南
  • 河北
  • 河南
  • 黑龙江
  • 湖北
  • 湖南
  • 吉林
  • 江苏
  • 江西
  • 辽宁
  • 内蒙古
  • 宁夏
  • 青海
  • 山东
  • 山西
  • 陕西
  • 上海
  • 四川
  • 天津
  • 新疆
  • 西藏
  • 云南
  • 浙江
  • 重庆
  • 香港
  • 澳门
  • 台湾
  • 国外
=
同类优质产品

在线询价

X

已经是会员?点击这里 [登录] 直接获取联系方式

会员登录

X

请输入账号

请输入密码

=

请输验证码

收藏该商铺

X
该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

X
您的留言已提交成功!我们将在第一时间回复您~
产品对比

对比框