产品简介

智能光功率计IntelligentOpticalPowerMeter1

详情介绍

智能光功率计

Intelligent Optical Power Meter

1.General

Intelligent Optical Power Meter is the newly developed multi-functional power meter. It equips with wide angle detector and it significantly improves the stability and the reliability. It features modern appearance, 3.5inches LCD display, easy operation, wide range, high accuracy, automatic frequency identifications, FC/SC/ST/LC universal connector.

The Type of Intelligent Optical Power Meter:

Ai---Wavelength:850~1650nm(1nm wavelength variable between the range)

Measurement Range:-70~+10dBm

Ci---Wavelength:850~1650nm (1nm wavelength variable between the range)

Measurement Range:-50~+30dBm

2.Specification

Type

Ai

Ci

Wavelength Type (nm)

850~1650

Detector Type

InGaAs φ1.0mm

Measurement Range (dBm)

-70~+10

-50~+30

Uncertainty

±5%

Power relative Measurement

0.01dBm

Power Supply

(4AA 1.5 alkaline battery),AC adapter 9V

Operation Temperature (°C)

-10~+60

Storage Temperature(°C)

-25~+70

Dimension (mm)

180*80*48

Weight (g)

360

Notice

1.Wavelength Range:Providing a standard operating wavelength λ from λmin to λmax,within the wavelength range, optical power meter works well within specifications

2.Power Measurement Range:can measure the range of Maximum power within specifications.

3.Uncertainty:the error of test result between defined optical power and standard one

3Components

1、Intelligent Optical Power Meter------------------------------------------------1pcs

2、User Manual-------------------------------------------------------------------1book

3、USB data wire------------------------------------------------------------------1pcs

4、CD------------------------------------------------------------------------------1pcs

5、Power Adapter------------------------------------------------------------------1pcs

6、Protect Jacket------------------------------------------------------------------1pcs

7、1.5V AA battery-----------------------------------------------------------------4pcs

8、Cleaning Cotton Swab---------------------------------------------------------1bag

4Function Directions

4.1Keyboard Directions

Sign

Functions

REF

Relative measurement mode

ZERO

Clean dark current

SAVE

Save the current test data

Power Switch / Auto-off function selection

C

Exit without saving the current operation

OK

Confirm key

Used to change wavelength value and wavelength calibration values add operation / menus Up Operation

Used to change wavelength values and wavelength calibration value subtraction operation / menus down operations

Set the figures when changing the wavelength and calibration, shift to the right

Set the figures when changing the wavelength and calibration, shift to the left

4.2 Display instrucitons

LCD displays the measured optical power value in dBm, mW, uW, nW as the unit; set arbitrary 1nm wavelength at the range of 850 ~ 1650nm; optical signal modulation frequency, battery capacity indicator, and automatic switch off status, etc.

5Usage Direction

5.1 Power on/off

1. Press key on panel board to switch on the unit.

2. Long press key(about 3 seconds) to switch off the unit.

5.2 Absolute Optical Power Measurement

1.Switch on the unit.

2.Set the operating wavelength, Press    key to choose the “Optical Power Meter"Modul on the top left of the screen, Click "OK" button to confirm.

3.Press Up、Down、Left、Right key to set the wavelength, Click "OK" button to confirm.

4.Access to the measured light,the LCD will displays the current measured values,including the absolute power of the linear and nonlinear values,if the measured light is modulating signal,then it will displays the modulation frequency of measured signal.

5.3 Relative Optical Power Measurement

1.Set the measuring wavelength。

2. In the absolute optical power measurement mode, access to the measured light, measure the current power value.

3. Press "REF" button, the current value of optical power as the current reference value (in dBm as the unit), this time the current absolute power value and the relative optical power is 0dB.

4.Access to another measuring light, displays the current measured values of the absolute power and relative power.

5.4 Save the test value

Access to measured signals,press“SAVE"button to save the current test data.

5.5 Check the saved test data

Press    button to choose “history memory" module on the top left of the screen, press "OK" button to confirm the test data was saved.

5.6 User self-calibration

Press    key to choose the Calibration Module on the top left of the screen, press "OK" button to confirm;

Press Up、Down、Left、Right key to set calibration value,Click“OK"button to confirm;